OMRON
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Voltage / current input >> K3HB-XAA-FLK3AT11 AC/DC24 Voltage and current panel meter

K3HB-XAA-FLK3AT11 AC/DC24 Voltage and current panel meter

OMRON K3HB-XAA-FLK3AT11 AC/DC24 Manual And Instructions
K3HB-XAA-FLK3AT11 AC/DC24 datasheetPDF datasheet

OMRON K3HB-XAA-FLK3AT11 AC/DC24 Product information and technical parameters:
Brand: OMRON
Name: Voltage and current panel meter
Model: K3HB-XAA-FLK3AT11 AC/DC24
Type of input: AC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceN

Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XAA-FLK3AT11 AC/DC24 K3HB-XAA-FLK3AT11 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurementOperating method: Incrementing, decrementing, and reversible,
(UP/DOWN A to F) (selectable with rotary DIP switch) K3HB-XAA-FLK3AT11 AC/DC24.
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable) K3HB-XAA-FLK3AT11 AC/DC24.
Set value read: Continuous mode, Reset mode (selectable).
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (8-mm high 7-segment LED, Up indicator).
Models: 6 digits; 2 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD with backlight.
Max. revolutions displayed (applicable encoder resolution):

1000 K3HB-XAA-FLK3AT11 AC/DC24. 0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Light-gray body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 K3HB-XAA-FLK3AT11 AC/DC24. 0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1.


...More relevant models >>>>