Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
External event input can be applied to a variety of measurement and identification situations.
Display type: UP display timer (increments from 0 to the set time).
Output type: Transistor output.
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 12 to 48 VDC.
Rated time: 0.001 to 9.999 s.
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series version cover a wide range of rated times; 9 K3HB-XAD-A-DRT1 AC100-240. 999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min
K3HB-XAD-A-DRT1 AC100-240
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. Input type: DC voltage/current K3HB-XAD-A-DRT1 AC100-240.
Supply voltage: 24 VAC/VDC.
Comparative Output Model: 2 relay contact outputs (SPST-NO).
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaling, front-panel forced-zero, zero-limit functions.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate) K3HB-XAD-A-DRT1 AC100-240.
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking. Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M. Supply voltage: 24 VAC; 12, 24 VDC K3HB-XAD-A-DRT1 AC100-240.
Time-limit contact: DPST-NO.
Short-time range model (0.1 s to 10 min).
Compact, Multi-function Timers,
for G2R Relay Socket.
The Push-In Plus Terminal Block Socket-compatible H3RN-@-B.
Timers in a black design jjoin the Compact, Multi-function H3RN Timers K3HB-XAD-A-DRT1 AC100-240.
Standard multiple time ranges and multiple operating modes.
UL listed.