OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> K8AK-PA1 Three-phase Asymmetry and Phase-sequence Phase-loss Relay

K8AK-PA1 Three-phase Asymmetry and Phase-sequence Phase-loss Relay

OMRON K8AK-PA1 Manual And Instructions
K8AK-PA1 datasheetPDF datasheet

OMRON K8AK-PA1 Product information and technical parameters:
Brand: OMRON
Name: Three-phase Asymmetry and Phase-sequence Phase-loss Relay
Model: K8AK-PA1
Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator.

Power supply (commercial AC power supply) power cut detector for monitoring and control device.
Instantaneous detection voltage drop, power failure, instantaneous power failure.
Small, easy to install DIN guide rail mounting type.
Input voltage is divided into AC100V, AC200V two specifications. Connector type: Plug and socket on cable ends K8AK-PA1.
Cable connection direction: Straight.
Applicable wire diameter: -- K8AK-PA1
Number of cores: 8.
Cable length: 5 m.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime K8AK-PA1.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Type: DC Bus Line Connector.
Number of Connectors: 10 (See note.).
DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures K8AK-PA1.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration.
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant. Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converrter K8AK-PA1.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection K8AK-PA1.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).


...More relevant models >>>>