Structure: Relays with Plug-in Terminals, With operation indicators.
absorption (DC coil specification only).
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
compliant with the UL, CSA, and SEV safety.
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
joined the series.
with the LR and VDE safety standards.
and 100/110 VDC).
VAC, 200/220 VAC and 100/110 VDC).
Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: No.
Applicable load: 25 A, 200 to 480 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications LY1N-D2.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents
LY1N-D2 (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Classification: Relay .
Structure: 4 poles.
Contact configuration: 3PST-NO/SPST-NC.
Rated Voltage: 12, 24 VDC LY1N-D2.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment LY1N-D2.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications. Isolation: Photocoupler.
Zero cross function: Yes.
Inddicator: Yes LY1N-D2.
Applicable output load(See note 2.): 25 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor efffectively absorbs external surges LY1N-D2.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.