With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete.
Number of poles: 3 poles.
Classification: Models with single contacts.
Rated voltage: Standard products, 100/110 or 200/220 VAC, 24 VDC;
Made-to-order items, 12, 24, 110/120, or 220/240 VAC, 12, 48, or 100/110 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays MK2P2-US.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them
MK2P2-US
MY(S) models with latching levers added for,
easier circuit checking. Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: No MK2P2-US.
Applicable load: 45 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification) MK2P2-US. Classification: Standard models.
Rated voltage: Standard products, 12, 24, 100/110, or 200/220 VAC,
12, 24, 48, or 100/110 VDC; Made-to-order items, 110/120 or 220/240 VAC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detectioon MK2P2-US. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection MK2P2-US.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.