OMRON
Home >> Products >> OMRON >> Relay >> General relay >> Relay for control cabinet >> MM4KP-JD Latching Relay

MM4KP-JD Latching Relay

OMRON MM4KP-JD Manual And Instructions
MM4KP-JD datasheetPDF datasheet

OMRON MM4KP-JD Product information and technical parameters:
Brand: OMRON
Name: Latching Relay
Model: MM4KP-JD
Type: Conforming to auxiliary power relay specifications.
Contact form: DPDT+DPST-NO.
Cased: Plug-in (octal pins) terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C.

Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 25 A, 100 to 240 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase MM4KP-JD.
Heaters Reduced Installation Work.
with DIN Track Mounting MM4KP-JD
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) MM4KP-JD.
Conforms to UL, CSA, and EN standards (TÜV certification). Type: Standard.
Contact form: 4PDT.
Open structure: Solder terminals.
Stable Contact Reliability and Long Life.
Easy to mount, wire, and use.
A large selection of models including various contact forms,
DC-switching models, and open models.
Mechanical life: 5,000,000 operations; electrical life,
(under rated load): 500,000 operations MM4KP-JD.
Models also available with built-in diodes and for use as,
auxiliary power relays. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detectioon MM4KP-JD. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection MM4KP-JD.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.


...More relevant models >>>>