Number of beams: 60.
Protective height: 1880mm.
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
MS4800-RM6 Resource Module.
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
to set functions.
Number of beams: 78.
Protective height: 1585mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions MSF4800-40-1800-XR2. Actuator: Plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action)
MSF4800-40-1800-XR2
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement MSF4800-40-1800-XR2.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action) MSF4800-40-1800-XR2.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selecctable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility MSF4800-40-1800-XR2.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads MSF4800-40-1800-XR2.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.