Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.070 A; 60 Hz, 0.060 A .
Rated input: 50 Hz, 13 W ; 60 Hz, 11 W .
Rated rotational speed: 50 Hz, 2550 r/min; 60 Hz, 3050 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 49.0 Pa; 60 Hz, 68.6 Pa.
Noise: 50 Hz, 33 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage R87F-A4A93HP.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
R87F-A4A93HP
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions R87F-A4A93HP. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Control supply voltage: 200 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element R87F-A4A93HP.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Capacity: 240 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 10 A.
Number of output branches: 6 branch outputs.
Communications functions: None.
Parameter settings: Changeable.
A New Type of Power Supply That.
Provides Safety and Maintainability. R87F-A4A93HP.
240- and 480-W power supplies with and digital circuit,
protectors in a single package.
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various moonitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature) R87F-A4A93HP.
Conforms to UL Class 2.
Mounts to DIN Rail.