OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Axial fan >> R87T-A1A05H AC Axial Fans

R87T-A1A05H AC Axial Fans

OMRON R87T-A1A05H Manual And Instructions
R87T-A1A05H datasheetPDF datasheet
R87T-A1A05H Connection Guide

OMRON R87T-A1A05H Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87T-A1A05H
Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.550 A; 60 Hz, 0.460 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) R87T-A1A05H.
Detect three-phase AC current for under and/or overcur,
rent using current converter R87T-A1A05H
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) R87T-A1A05H.
LED operation indicator.
UL/CSA approval (SDV-F@). Type: With cable.
No. of poles: 4.
Lock: Rear lock.
Cable length: 0.5 m.
Minimum order: 10.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock R87T-A1A05H.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Cable core number: 4.
Cable outlet direction: L type.
Cable length: 5m.
Save time, save maintenance cost,
With a waterproof connector environment and strong tolerance of FA.
For IP67, the FA 94V-0 connector small special flammability.
The wiring system makes the device more maintainable connector,
And reduce the downtime of equipment.
Introduction of connector and modular connector with cable.
A modular connector crimpping type, welding type, screw connection type 3 R87T-A1A05H.
With the cable connector is obtained UL certification of products.
According to IEC61076-2-101 (IEC60947-5-2), NECA4202. No. of inputs: 16.
No. of poles: 20.
Mounted Connector model: XGG4A-2031 R87T-A1A05H.
Cable Connector model: XG4M-2030-T.
Common terminal provided.
Use for either PLC Input Unit or Output,
Unit merely by changing short bar.


...More relevant models >>>>
Related model