Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.550 A; 60 Hz, 0.460 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
Control power supply voltage: 125 VDC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) R87T-A1A05H.
Detect three-phase AC current for under and/or overcur,
rent using current converter
R87T-A1A05H
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) R87T-A1A05H.
LED operation indicator.
UL/CSA approval (SDV-F@). Type: With cable.
No. of poles: 4.
Lock: Rear lock.
Cable length: 0.5 m.
Minimum order: 10.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock R87T-A1A05H.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Cable core number: 4.
Cable outlet direction: L type.
Cable length: 5m.
Save time, save maintenance cost,
With a waterproof connector environment and strong tolerance of FA.
For IP67, the FA 94V-0 connector small special flammability.
The wiring system makes the device more maintainable connector,
And reduce the downtime of equipment.
Introduction of connector and modular connector with cable.
A modular connector crimpping type, welding type, screw connection type 3 R87T-A1A05H.
With the cable connector is obtained UL certification of products.
According to IEC61076-2-101 (IEC60947-5-2), NECA4202. No. of inputs: 16.
No. of poles: 20.
Mounted Connector model: XGG4A-2031 R87T-A1A05H.
Cable Connector model: XG4M-2030-T.
Common terminal provided.
Use for either PLC Input Unit or Output,
Unit merely by changing short bar.