OMRON R87T-A6A15HP Product information and technical parameters:
Brand: OMRON
Name: AC Axial Fans
Model: R87T-A6A15HP
Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.105 A; 60 Hz, 0.095 A .
Rated input: 50 Hz, 20 W; 60 Hz, 18 W.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 66.6 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Cable: With cable.
Connector: Connectors on both cable ends.
Cable length L: 0.5 m.
Minimum order: 5.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
Conventional M8 screw-mounting models are available along with,
S8 snap-in models that connect and disconnect with one touch R87T-A6A15HP.
Ideal for a wide variety of FA and OA applications R87T-A6A15HP
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles. Control power supply voltage: 24 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V R87T-A6A15HP.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection R87T-A6A15HP.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Type: Flat Cable.
Terminal Block: Terminal block with M3 screws.
Connector: Flat Cable Connectors*1.
No. of poles: 34.
Simplifies Connector and terminal,
block replacement, and requires less,
in-panel wiring.
Mount to DIN Track or via screws.
MIL Flat Cable Connectors and Multi-pole, Square,
Connectors are standard.
Terminal blocks available with either M3 or M3.5 screws.
Connectingg Cables for Programmable Controllers,
available (sold separately) R87T-A6A15HP. Model: PY (back-mounting), page 15, PCB terminals.
Number of pins: 14 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Modelss,
Models available with finger protection R87T-A6A15HP.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available.


...More relevant models >>>>
Related model