Capacity: 240 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 10 A.
Number of output branches: 6 branch outputs.
Communications functions: RS-485.
Parameter settings: Changeable .
A New Type of Power Supply That.
Provides Safety and Maintainability.
protectors in a single package.
set at 0.1-A increments.
Startup and shutdown sequence control included.
temperature).
Conforms to UL Class 2.
Mounts to DIN Rail.
Cable with connector (1 to 3) /G79-_C-_-_.
L size: A, 2000mm; B, 1750mm; C, 1500mm.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage S8AS-24006R.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.550 A; 60 Hz, 0.460 A
S8AS-24006R
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans S8AS-24006R.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product S8AS-24006R. Check the information given for available models of Axial fans and,
the information in Characteristics. Ideal for Food Processing Machines or Other,
Applications that Require Watertightness,
Four sizes (96 × 96, 72 × 72, 48 × 96, 48 × 48) are available.
Conforms to IP66 or NEMA4 (indoors). Model: DGR-H (67G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / innternal tributaries S8AS-24006R.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident S8AS-24006R.
2 stage cross terminal stand with cover with convenient wiring.