OMRON S8JC-Z01505C Product information and technical parameters:
Brand: OMRON
Name: Switching Mode Power Supply
Model: S8JC-Z01505C
Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 5VDC.
Output current: 3.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time.

Power ratings: 30 W.
Output voltage: 24 V.
Output current: 1.3 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models S8JC-Z01505C.
Lineup of models with from 5 to 48-VDC output.
voltages S8JC-Z01505C
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models) S8JC-Z01505C.
The top class in industry for compact size.
Boost current output (some models excluded). Control supply voltage: 100/200 VAC; With voltage fluctuation compensation.
Operating current: 0.25 to 0.5 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal S8JC-Z01505C.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.190 A; 60 Hz, 0.160 A .
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2450 r/min; 60 Hz, 2700 r/min.
Maximum flow rate: 50 Hz, 2.2 m3/min; 60 Hz, 2.5 m3/min.
Maximum static pressure: 50 Hz, 63.7 Pa; 60 Hz, 63.7 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 42 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and mettal-bladed models,
(28 type) included in series S8JC-Z01505C.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product S8JC-Z01505C. Check the information given for available models of Axial fans and,
the information in Characteristics.