Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 100W.
Output voltage: 48VDC.
Output current: 2.3A.
The new power S8JC-ZS has a CE certification mark to market.
Through the DIN guide rail installation, significant savings in time.
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load) S8JC-Z10048CD.
Output relay can be switched between normally open and normally closed
S8JC-Z10048CD
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan) S8JC-Z10048CD.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity S8JC-Z10048CD.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Power ratings: 30 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 5 V.
Output current: 5 A.
Boost Current: 6 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety sstandards:
UL508/60950-1, CSA C22 S8JC-Z10048CD. 2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 4800-W models) S8JC-Z10048CD.
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1.