OMRON S8VM-01505D Product information and technical parameters:
Brand: OMRON
Name: Switching Mode Power Supply
Model: S8VM-01505D
Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)

Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.260 A; 60 Hz, 0.220 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 4.8 m3/min; 60 Hz, 5 S8VM-01505D. 7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB S8VM-01505D
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series S8VM-01505D.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Time specification: Instantaneous type.
Current setting range: 2 to 8 A S8VM-01505D.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is iindicated from the start of operation S8VM-01505D.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions S8VM-01505D. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>