OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VM-01515CD Switching Mode Power Supply

S8VM-01515CD Switching Mode Power Supply

OMRON S8VM-01515CD Manual And Instructions
S8VM-01515CD EtherCAT(R) Connection Guide

OMRON S8VM-01515CD Product information and technical parameters:
Brand: OMRON
Name: Switching Mode Power Supply
Model: S8VM-01515CD
Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 15V.
Output current: 1A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"

Cable specifications: Oil-resistant Polyurethane Cable.
Cable length L: 10 m.
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 1.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors S8VM-01515CD.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock S8VM-01515CD
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: P5 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz S8VM-01515CD.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7.5A cos (AC 250V maximum diameter =0.4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times.
Relay control output for circuit breaker switching.
Quality: about 0.5kg.
External: Mount Searl N1 S8VM-01515CD. 5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.
Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 300W.
Output voltage: 12V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
SSupport finger touch protection to prevent electric shock S8VM-01515CD.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer S8VM-01515CD. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
")


...More relevant models >>>>