Category: incidental cover with under voltage detection function.
Structure: bottom mounting type.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Alarm output: -.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 200/220/240 VAC.
Overcurrent detection: Inverse type.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available S8VM-01524A.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring
S8VM-01524A
DIN sized (48 mm x 96 mm). Compact DC-DC UPS with a DIN rail for,
mounting, best suited for prevention of,
voltage drop and power failure in,
industrial-purpose computers.
(IPC)/controllers.
System reliability greatly improved because.
24VDC power supply is backed up for a certain S8VM-01524A.
period of time in the event of voltage drop or power failure.
Compactness, weight reduction, and long battery life,
realized thanks to the adoption of a lithium-ion battery.
Push-in terminal block adopted for the power input and,
output I/F.
Shutdown in conjunction with the industrial,
purpose computer (IPC) or controller realized,
by the USB/RS-232C/I/O port installed in the UPS S8VM-01524A. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 5 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 OOutput standards S8VM-01524A.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8VM-01524A.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)