OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VS-24024BP Switch Mode Power Supply

S8VS-24024BP Switch Mode Power Supply

OMRON S8VS-24024BP Manual And Instructions
S8VS-24024BP datasheetPDF datasheet
S8VS-24024BP Installation and Operating Manual
S8VS-24024BP Installation and Operating Manual

OMRON S8VS-24024BP Product information and technical parameters:
Brand: OMRON
Name: Switch Mode Power Supply
Model: S8VS-24024BP
Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)

Type: cable plug connector.
Contact number: 3.
Wiring simple and e-CON * specifications for connectors;
Ideal choice for connecting sensors.
The connection of the spring clip which is verified by the industry is adopted.
Wiring is simple, no special tools required,
Can be re wiring (maintenance).
Acceptable range for each connector
Stranded AWG28 (0 S8VS-24024BP. 08mm2) ~ AWG20 (0.5mm2),
Any core wire size between S8VS-24024BP
(outer diameter: no more than 1.5mm).
A clamp capable of simultaneously connecting 4 lines when a connection is also provided.
UL standard (Document No. E103202) identified as a standard product.
Cable connector with the UL standard certification of products.
"Time specification: Instantaneous type S8VS-24024BP.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button S8VS-24024BP.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. No. of digits: 4.
Display color: Green.
Input method: Dynamic.
Logic: Positive.
Display contents: Numerals and units.
A Series of Three- to Five-digit Digital.
Display Units with a Character Height of,
14 mm. Models available with either red or,
green displays.
Red or green displays with a character height of 14 mm are,
available for a variety of applications and locationss S8VS-24024BP.
Miniature design with a 50-mm depth.
Incorporating a connector, thus saving wiring effort.
Connecting to OMRON''s PLCs via dedicated PLC cables (sold separately).
Units and minus symbols are displayed (three- and four-digit modell only) S8VS-24024BP.
Incorporating a zero suppression function.
The power supply can freely change between 12 and 24 VDC.
CE Marking. UL certification approval.


...More relevant models >>>>