OMRON
Home >> Products >> OMRON >> Master slave station products >> CompoBus/S >> SRT2-OD08CL-1 Waterproof Terminals

SRT2-OD08CL-1 Waterproof Terminals

OMRON SRT2-OD08CL-1 Manual And Instructions
SRT2-OD08CL-1 datasheetPDF datasheet
SRT2-OD08CL-1 HOST CONNECTION MANUAL
SRT2-OD08CL-1 User's Manual

OMRON SRT2-OD08CL-1 Product information and technical parameters:
Brand: OMRON
Name: Waterproof Terminals
Model: SRT2-OD08CL-1
Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enables direct on-site,
mounting.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (8-point models).
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.

Short/disconnection detection: Supported.
Specifications: Outputs, PNP (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring SRT2-OD08CL-1.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance SRT2-OD08CL-1
Single-step wiring by simply inserting pole terminals. Name: Slice I/O Units; Analog I/O Units.
Specifications: Analog output (voltage).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet SRT2-OD08CL-1.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error SRT2-OD08CL-1. Unit: Terminal block model.
I/O classification: Digital output.
Internal I/O common: NPN (- common).
I/O points: 16.
I/O connections: M3 terminal board.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit SRT2-OD08CL-1. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software SRT2-OD08CL-1.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.


...More relevant models >>>>