Lock method: Front lock.
Pin shape: DIP pin.
Applicable wire diameter: AWG20 to 28.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Cable /G79-Y_C with loose wire connecting terminal.
L size: 1000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 115V.
Allowable voltage range: 85 to 110% of rated voltage XS2P-A422-1.
Frequency: 50/60Hz.
Rated current: 60Hz--0
XS2P-A422-1175A; 50Hz--0.194A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70.9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB.
The axial flow fan with the best cooling is realized.
The design of low noise, high life and good environmental adaptability is considered XS2P-A422-1.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
New waterproof type AC axial fan type R87F-A - A16H-WR,
(protection structure IP65).
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich. Category: incidental cover type.
Structure: DIN guide rail mounting type XS2P-A422-1.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals))
Support finger touch protection to prevent electric shock XS2P-A422-1.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer XS2P-A422-1. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"