Name: Expansion Units.
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Unit: 10 points (6 inputs/4outputs); Connector model.
Inputs: 6 points at 24 VDC.
Outputs: 4 transistor sinking outputs.
Clock: Yes.
Ultra-compact, Thin-profile CPM2C CPU.
Unit with CompoBus/S Master Offering.
High-speed Bus Communications with,
No Complicated Wiring.
Ultra-compact, thin-profile design ideal for on-site,
applications XWT-OD16-1.
Ultra-compact at 40 x 90 x 65 mm (W x H x D) with
XWT-OD16-1
10 I/O points and CompoBus/S Master offers.
versatile expandability to construct systems.
meeting on-site needs.
A large number of expansion I/O points reduces,
system construction cost.
Up to three Expansion Terminals can be,
connected. Furthermore, CompoBus/S Remote,
Terminals can be used for expansion I/O points XWT-OD16-1.
Not only in-panel wiring but also external wiring is,
simplified. Furthermore, the miniaturization of the,
control panel reduces cable, terminal block, and wiring costs.
Easy System Designing, Modification, and Expan sion.
CompoBus/S Remote Terminals with high-speed.
bus communications and no complicated wiring.
can be used as expansion terminal blocks with,
minimal modifications as long as room for,
expansion is reserved at the designing stage XWT-OD16-1.
A calendar/clock ensures easy machinery control,
including data collection and error logs with date,
and time stamps. This functionality can be used as,
a weekly timer as well. Input/Output: Outputs.
Internal I/O circuit common: NPN (– common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-pproof,
construction (IP67) enables direct on-site,
mounting XWT-OD16-1.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) XWT-OD16-1.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.