OMRON
Home >> Products >> OMRON >> Master slave station products >> CompoNet >> XWT-VMD08S-1 Expansion Units

XWT-VMD08S-1 Expansion Units

OMRON XWT-VMD08S-1 Manual And Instructions
XWT-VMD08S-1 datasheetPDF datasheet

OMRON XWT-VMD08S-1 Product information and technical parameters:
Brand: OMRON
Name: Expansion Units
Model: XWT-VMD08S-1
Name: Expansion Units e-CON Connector type.
Specifications:Digital inputs and outputs;
4 inputs/ 4 outputs; PNP;
One Expansion Unit can be mounted to one,
CRT1-VAD02@@D or CRT1-VDA02@@D Analog I/O Slave Unit.
Standards: --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system XWT-VMD08S-1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction XWT-VMD08S-1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Output.
Internal I/O circuit common: PNP (+ common) XWT-VMD08S-1.
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits XWT-VMD08S-1.
DIN track mounting and screw mounting are both supported.
I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H).
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection. Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansionn unit per one I/O terminal unit XWT-VMD08S-1. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software XWT-VMD08S-1.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.


...More relevant models >>>>