I/O points: 256 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 3 K.
RS-232C port: no.Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet C500-RT001-PV1.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-leveel I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
C500-RT001-PV1.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Name: Connector.
Model: C200H-CE001 C500-RT001-PV1.CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 36; Output, 24 OMRON C500-RT001-PV1.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams OMRON C500-RT001-PV1. For 3-slot Backplane.Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (NPN) output, 2 loops OMRON C500-RT001-PV1.Model: CPM2C-16ETC. Units with transistor outputs only.
1 Fujitsu connector.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.C500-OA I/O Unit Triac Output 32 pts C500-OA225.
AC250V 1A.Model: C500-BC091(3G2A5-BC091).
8 slots(6 linkable slots).
Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 8 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.122A; 26V, 0 C500-RT001-PV1.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals.