Specification: 16 input points, 16 output points.Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet C500-AD007.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribbution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
C500-AD007.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. v
Model: CPM2C-20C1DT1C-D. CPU Unit: Units with 20 I/O points C500-AD007.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: Yes.Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface OMRON C500-AD007.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No. of axes: 16 axes.
No. of unit numbers allocated: 1 OMRON C500-AD007.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II OMRON C500-AD007.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C500-AD007.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.