Name: Temperature Control Module.
Model: C200H-TC103.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Current output.Unit type: CS1 Basic I/O Units.
Product name: DC Input/Transistor Output Unit.
Specifications: 24 VDC, 6 mA 32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No CJ1M-CPU13-ETN INSTRUCTIONS REFERENCE MANUAL
CJ1M-CPU13-ETN
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 input words and 2 output words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CJ1M-CPU13-ETN INSTRUCTIONS REFERENCE MANUAL. C500-ID I/O Unit DC Input 32 pts C500-ID218CN(3G2A5-ID218CN).
DC12-24V 10mA.Model : C500-MR831.Model: C200H-OD218.
No. of points: 32 pts.
Specifications: nit 4.5 VDC, 16 mA to 26.4 VDC, 100 mA. .
Weight: 180g max.Model : C500-LK103-P.
APF/ PCF.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1 CJ1M-CPU13-ETN INSTRUCTIONS REFERENCE MANUAL. 25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ1M-CPU13-ETN Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1M-CPU13-ETN Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.