Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4A-0017N INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
D4A-0017N
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Drive lever: short swing lever type D4A-0017N INSTRUCTION sheet.
Specifications: plastic wire terminal.
The protection structure is in conformity with the JIS''s anti immersion type, IP67 IEC (except for the terminal part).
Can be used in the environment temperature -40 ~ +85.
Through the use of gold alloy bar, contact springs to achieve longevity and high contact reliability. A reliable basic switch with an external lever
Can use 0.1A, 6A, 11A, 16A and 21A models,
All models have a self - cleaning connection D4A-0017N INSTRUCTION sheet.
Custom leverage can be used externally or internally,
And 2 fixed positions of the external lever.
Consistent with EN61058-1 and UL1054.
Model composition:
D3V- - - - - - - - - - - - -
The 4 5 6 7 8 9
Rated value
AC250V 21: 20 (4) A
AC250V 16: 16 (3) A
AC250V 11: 11 (3) A
AC250V 6: 6 (2) A
AC125V 0.1A 01:
Contact interval
No mark: 1mm (Gap F)
G:0.5mm (Gap G)
Driving rod
No mark: needle button type
1: short swing rod type
2: swing lever type
3: long swing rod type
R 4: type swing lever type
5: ball short swing rod type
6: ball type
The installation position of the sensors
No mark: internal installation, the button switch is far from the reference position
M: external installation, the button switch is far from the reference position
K: external installation, the button switch is close to the reference position.
Contact the specifications
SP DT 1:
SP ST-NC 2:
SP ST-NO 3:
The terminal specificatioon
A: welding terminal
#187 C2: type terminal
#250 C: type terminal
The maximum operating force (OF)
5: 1 D4A-0017N Manual. 96 N
4A: 1.23 N
4: 0.98 N
3: 0.49 N
2: 0.25 N
Note that the numerical value is a needle like button type.
We take tthe size of mounting hole
No mark: 3 D4A-0017N Manual. 1mm
2.9mm K:
9 special code
No mark: Standard
H: high temperature (125 degrees C)
E: special rating: 21 (8) A