Actuator: Pin plunger.
Type: M16.
Operation Indicator: Provided.
Repeat accuracy: 3 µm max.
Operating force OF max: 2.45 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work D4N-4A32R INSTRUCTION sheet.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes
D4N-4A32R
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installation and maintenance. Actuator: Roller lever (resin lever, resin roller) D4N-4A32R INSTRUCTION sheet.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-4A32R INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: 1 A at 125 VAC.
LED indicator: With indicator.
Actuator: Sealed pin plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Informmation on approved models D4N-4A32R Manual. ) Drive rod: R type swing lever type.
Specifications: plastic wire terminal.
The protection structure is in conformity with the JIS''s anti immersion type, IP67 IEC (except for the terminal part).
Can bee used in the environment temperature -40 ~ +85 D4N-4A32R Manual.
Through the use of gold alloy bar, contact springs to achieve longevity and high contact reliability.