A small limit switch for the Chinese market.
Small longitudinal Asian standard size.
Miniaturization design of the 1/3 of the OMRON longitudinal type limit switch.
Terminal fully open structure, easy wiring.
RoHS correspondence.
Protection structure IP65. Type: 1-Conduit.
Contact configuration: Slow-action; 1NC/1NO D4N-7B2GR INSTRUCTION sheet.
Conduit opening/Connector: G1/2.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch
D4N-7B2GR
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standardized gold-clad contacts provide high,
contact reliability D4N-7B2GR INSTRUCTION sheet.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) D4N-7B2GR INSTRUCTION sheet.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits aand two monitor contacts provide an,
array of monitoring patterns D4N-7B2GR Manual.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4N-7B2GR Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.