Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
The type of the drive lever: one way action roller rocker type (horizontal action).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) D4N-4B2GR.
Forced open action structure
D4N-4B2GR
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now D4N-4B2GR.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2 D4N-4B2GR.
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 68.
Protective height: 2040mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Actuator: Plunger.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4N-4B2GR.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-4B2GR.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.