Operation indicator: With operating indication; Standard load.
Ratings: 4 A at 30 VDC.
Actuator: Roller lever (high sensitivity model).
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4NL-2GFA-B4 INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection
D4NL-2GFA-B4
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4NL-2GFA-B4 INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Measurement range: 1 mm.
Resolution: 0.1 µm.
Operating force: Approx. 0.7 N.
Five Types of Sensor for Use in a Wide D4NL-2GFA-B4 INSTRUCTION sheet.
Range of Environments.
D5SN-S01/-S04/-S04-L Sensors have a compact and light,
weight design with an ultra-small diameter of 6 mm.
The D5SN-S01 offers a high resolution of 0.1 µm.
D5SN-M05/-M10 Sensors have a robust construction and can,
withstand a horizontal load of 5 N.
D5SN-S01/-S04/-M05/-M10 Sensors ensure IP67 degree of,
protection.
All Sensors have an insulated design. Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 D4NL-2GFA-B4 Manual.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4NL-2GFA-B4 Manual.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.