E3JK-R4S3 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 5m.
Output state: when the light into the ON; light shading ON.
Output: DC no contact,
2 types of cost reductionCase color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling E5AC-CC4DSM-005 INSTRUCTION Manual.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --
E5AC-CC4DSM-005
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5AC-CC4DSM-005 INSTRUCTION Manual. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AC-CC4DSM-005 INSTRUCTION Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 4 points: Pulse voltage and Pulse voltage/current,
and Current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 6; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using modells with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5AC-CC4DSM-005 Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5AC-CC4DSM-005 Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.