OMRON
Home >> Download >> OMRON >> Manual Download >> E5ER-C4B INSTRUCTION Manual ()

E5ER-C4B INSTRUCTION Manual ()

Brand: OMRON
Product model: E5ER-C4B
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 7.41MB
Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater E5ER-C4B INSTRUCTION Manual.
Event entry point: 2 E5ER-C4B
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E5ER-C4B INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5ER-C4B INSTRUCTION Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automaticc / manual, RUN/STOP, alarm), interactive display PV/SV E5ER-C4B Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5ER-C4B Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Digital regulator
E5ER-C4B
OMRON Digital regulator E5ER-C4B
Ontology: asic. Size: 48 x 96mm. Type: asic
OMRON
Digital regulator
E5ER-CT3DW-FLK
OMRON Digital regulator E5ER-CT3DW-FLK
Ontology: asic. Size: 48 x 96mm. Type: 2 in
OMRON
Digital Controllers
E5AR-C4B-DRT
OMRON Digital Controllers E5AR-C4B-DRT
Size: 96 × 96 mm. Control type: Basic contro
OMRON
Digital Controllers
E5AR-C4B
OMRON Digital Controllers E5AR-C4B
Size: 96 × 96 mm. Control type: Basic contro