Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
Units cannot be mounted; 3 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes CRT1-MD16TA-1 PDF datasheet.
CPU Bus Units: CS-series CPU Bus Unit, Yes
CRT1-MD16TA-1
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: MIL Connectors.
Specifications: Outputs; 32 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CRT1-MD16TA-1 PDF datasheet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CRT1-MD16TA-1 PDF datasheet. Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 64 inputs;
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
Fujitsu connector; No. of words allocated, 4 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V tto 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point CRT1-MD16TA-1 PDF catalog.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.20A; 26V, 0.20A.
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Anaalog Input Units for converting,
analog input signals into binary data CRT1-MD16TA-1 PDF catalog.
Analog Output Units for converting ,
binary data into analog output signals.