Input type: DC current input.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K2CM-Q1HA PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K2CM-Q1HA
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet typeCategory: external supply 100mA DC10V K2CM-Q1HA PDF datasheet.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-Q1HA PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputApplicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor K2CM-Q1HA PDF catalog.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss K2CM-Q1HA PDF catalog.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.