K3HB-VLC-L2ET11 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-VLC-L2ET11 AC100-240
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Type of input: AC current input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-VLC-L2ET11 AC100-240 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC-L2ET11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DevType of input: AC current input K3HB-VLC-L2ET11 AC100-240 PDF datasheet.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC-L2ET11 AC100-240 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemFunction: Temperature monitoring.
Power supply voltage: 24 VAC/DC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even iif one heater el,
ement among several heater elements has been burned out K3HB-VLC-L2ET11 AC100-240 PDF catalog.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-VLC-L2ET11 AC100-240 PDF catalog.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
Related products
OMRON
Rotating pulse meter
K3HB-RPB-AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Voltage and current panel meter
K3HB-XAD-L1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-L1AT11 AC100-240
Input type: DC current input. Output type: l
OMRON
Time interval table
K3HB-PPB-L2AT11 AC100-240
OMRON Time interval table K3HB-PPB-L2AT11 AC100-240
Input type: PNP input type. Event input term