K3HB-XAD-L1AT11 AC100-240 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-XAD-L1AT11 AC100-240
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K3HB-XAD-L1AT11 AC100-240 PDF datasheet.
Manual resetting and automatically resetting supported by one Relay K3HB-XAD-L1AT11 AC100-240
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Control supply voltage: 220 VAC; With voltage fluctuation compensation K3HB-XAD-L1AT11 AC100-240 PDF datasheet.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K3HB-XAD-L1AT11 AC100-240 PDF datasheet.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start off operation K3HB-XAD-L1AT11 AC100-240 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAD-L1AT11 AC100-240 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-ET11 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Time interval table
K3HB-PPB-FLK3AT11 AC100-240
OMRON Time interval table K3HB-PPB-FLK3AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Voltage and current panel meter
K3HB-XAD-FLK1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-FLK1AT11 AC100-240
Input type: DC current input. Output type: c
OMRON
Rotating pulse meter
K3HB-RPB-FLK1AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-FLK1AT11 AC100-240
Input type: PNP input type. Event input term