OMRON
Home >> Download >> OMRON >> Catalog Download >> K3HB-XVA-DRT1 AC/DC24 PDF datasheet (datasheet)

K3HB-XVA-DRT1 AC/DC24 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-XVA-DRT1 AC/DC24
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Type of input: AC voltage input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth K3HB-XVA-DRT1 AC/DC24 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XVA-DRT1 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemStandard function model: detection of under voltage K3HB-XVA-DRT1 AC/DC24 PDF datasheet.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side) K3HB-XVA-DRT1 AC/DC24 PDF datasheet.
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.
The control power of the relay is not needed, which avoids the trouble of wiring.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manuaal resetting and automatically resetting supported by one Relay K3HB-XVA-DRT1 AC/DC24 PDF catalog.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-XVA-DRT1 AC/DC24 PDF catalog.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-B-DRT1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-B-DRT1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Voltage and current panel meter
K3HB-XVD-A-DRT1 AC/DC24
OMRON Voltage and current panel meter K3HB-XVD-A-DRT1 AC/DC24
Input type: DC voltage input type. Output ty
OMRON
Voltage and current panel meter
K3HB-XAA-DRT1 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-DRT1 AC/DC24
Type of input: AC current input. Output type
OMRON
Rotating pulse meter
K3HB-RNB-A-DRT1 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-A-DRT1 AC/DC24V
Input type: NPN/ voltage pulse input type. E