OMRON
Home >> Download >> OMRON >> Catalog Download >> K3HB-XVA-L2AT11 AC/DC24 PDF datasheet (datasheet)

K3HB-XVA-L2AT11 AC/DC24 PDF datasheet (datasheet)

Brand: OMRON
Product model: K3HB-XVA-L2AT11 AC/DC24
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-XVA-L2AT11 AC/DC24 PDF datasheet K3HB-XVA-L2AT11 AC/DC24
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC K3HB-XVA-L2AT11 AC/DC24 PDF datasheet.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple or platinum resistance thermometer.
Setting units (setting range): Setting unit: 1°C or 1°F (0 to 999°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22 K3HB-XVA-L2AT11 AC/DC24 PDF datasheet. 5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED indicator.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and ccyclic control K3HB-XVA-L2AT11 AC/DC24 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-XVA-L2AT11 AC/DC24 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Voltage and current panel meter
K3HB-XAD-AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAD-AT11 AC/DC24
Input type: DC current input. Output type: t
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC/DC24
Type of input: AC current input. Output type
OMRON
Rotating pulse meter
K3HB-RNB-AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XVA-L2AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-L2AT11 AC100-240
Type of input: AC voltage input. Output type