Brand: OMRON
Product model: K8AB-AS1 AC200/230V
Name: Single-phase Current Relay
Sort: PDF datasheet
File language: English
File size: 0.81MB
Type of input: AC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K8AB-AS1 AC200/230V PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K8AB-AS1 AC200/230V
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviTime specification: Instantaneous type K8AB-AS1 AC200/230V PDF datasheet.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8AB-AS1 AC200/230V PDF datasheet.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, aand cyclic control K8AB-AS1 AC200/230V PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K8AB-AS1 AC200/230V PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Single-phase Current Relay
K8AB-AS1 AC100/115V
OMRON Single-phase Current Relay K8AB-AS1 AC100/115V
Measuring current: 2 to 20 mA AC/DC, 10 to 10
OMRON
Single-phase Current Relay
K8AB-AS2 AC200/230V
OMRON Single-phase Current Relay K8AB-AS2 AC200/230V
Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5
OMRON
Single-phase Voltage Relay
K8AB-VS2 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS2 AC200/230V
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V
OMRON
Single-phase Voltage Relay
K8AB-VS1 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS1 AC200/230V
Measuring voltage: 6 to 60 mV AC/DC, 10 to 10