K8AB-AS3 AC200/230V PDF datasheet (datasheet)

Brand: OMRON
Product model: K8AB-AS3 AC200/230V
Name: Single-phase Current Relay
Sort: PDF datasheet
File language: English
File size: 0.81MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V K8AB-AS3 AC200/230V PDF datasheet.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K8AB-AS3 AC200/230V
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurableMeasuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC K8AB-AS3 AC200/230V PDF datasheet.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported K8AB-AS3 AC200/230V PDF datasheet.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Wiring distance: Standard usage, Wiring cable: 50 m max. Sensing Bands: 10 m max.
Disconnection detection: Supported.
Socket terminals: Screw Terminal Block P2RF-08/-08-E.
Reliable Sensitive Liquid Sensors,
for Stable Detection of Liquid.
Chemicals with Low Conductivity,
and Water Leakage.
New models available that are compatible with Push,
In Plus Terminal Block Sockets.
UL listed when used with Push-In Plus Terminal,
Block Sockets.
Sensor disconnection detection (K7L-AT50D@/-UD@).
Models for long-distance wiring to 400 m.
Ribbon Electrode Bands and Point Sensors available. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the sttart of operation K8AB-AS3 AC200/230V PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-AS3 AC200/230V PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Single-phase Current Relay
K8AB-AS3 AC200/230V
OMRON Single-phase Current Relay K8AB-AS3 AC200/230V
Measuring current: 10 to 100 A AC, 20 to 200
OMRON
Single-phase Current Relay
K8AB-AS2 AC200/230V
OMRON Single-phase Current Relay K8AB-AS2 AC200/230V
Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5
OMRON
Single-phase Voltage Relay
K8AB-VS3 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VS3 AC200/230V
Measuring voltage: 20 to 200 V AC/DC, 30 to 3
OMRON
Single-phase Voltage Relay
K8AB-VW3 AC200/230V
OMRON Single-phase Voltage Relay K8AB-VW3 AC200/230V
Measuring voltage: 20 to 200 V AC/DC, 30 to 3