Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
PNP outputs (pulses).
No. of unit numbers allocated: 2 C200H-ASC11 HOST CONNECTION MANUAL.
Current consumption: 5V, 0.25A; 24V, --
C200H-ASC11
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Product name: E@@S type CPU Units with 20 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 12; Outputs, 8;
Output type: Relay C200H-ASC11 HOST CONNECTION MANUAL.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.17A; 24 V,0.08A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality C200H-ASC11 HOST CONNECTION MANUAL.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: CPM2C-20C1DR-D. CPU Unit: Units with 20 I/O points.
I/O terminal block.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: Yes.C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD001(3G2A5-AD001).
Input: 2 pts.
Specification: +1~+5V, 4~20mA.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems C200H-ASC11 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems C200H-ASC11 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.