Applicable CPU Units: CQM1H-CPU51/61.
Mounting locations and number of Boards: 1 Board can be mounted in either slot 1 or slot 2.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 60 g max.Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Open-collector output;
Number of control axes : 4 axes C200H-TV101 SETUP MANUAL
C200H-TV101
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.36A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines C200H-TV101 SETUP MANUAL.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control. Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit C200H-TV101 SETUP MANUAL.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line.
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced C200H-TV101 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee C200H-TV101 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.