Number of inputs: 8 pts.
Input Voltage: 200 to 240VAC.
Input Current: 6 mA.Name: Temperature Control Module.
Model: C200H-TC101.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Transistor output.Specifications: Optical cable(H-PCF cable).Output method: Relay.
Inputs: 12.
Outputs: 8 CJ1M-CPU12 Operation Manual. Power supply: DC power supply.
Output method: Transistor output sink type
CJ1M-CPU12
Inputs points: 6 points.
Outputs points: 4 points.Required when supplying backup power.
For 2 Units.Model : C500-PS223-E.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.I/O Control UnitUnit type: CS1 CPU Bus Units.
Product Name: MECHATROLINK-II,
compatible Position Control Unit.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications CJ1M-CPU12 Operation Manual.
Direct operation by ladder,
programming, Control mode:
Position control, speed control,
or torque control; No. of axes: 16.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management CJ1M-CPU12 Operation Manual.
Control Servos for up to 16 axes,
in a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Size: 60mm.
Type: 4 lines.
Lighting voltage: DC24V.
Color: red.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting.
Large tactile buttons are easier to touch.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the.
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. NO. OF I/O SLOTS: 11 SLOTSUnit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector,
PNP outputs (pulses) CJ1M-CPU12 Manual.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output CJ1M-CPU12 Manual.