Model: C200H-IA222.
No. of inputs: 16 pts.
Input voltage: 200 to 240 VAC, +10%/–15%.
Input current: 10mA, 200VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tioRequired for Analog Input and Output Units: For two Analog Units CJ1M-CPU22 Operation Manual. Model: C200HW-BI031.
No. of I/O slots: 3 slots
CJ1M-CPU22Name: e-CON Connectors.
Specifications: Outputs; 8 outputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CJ1M-CPU22 Operation Manual.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units CJ1M-CPU22 Operation Manual.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.
Name: SYSMAC LINK Module.
Model: C200HW-SLK23.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.Model: C200H-CN131.
Cable length: 1, 000cm.Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming;
No. of axes: 4 axes.
No. of unit numbers alllocated: 1 CJ1M-CPU22 Manual.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency.
The EtherCAT communications with,
100Mbps bbaud rate enables fast,
and accurate position control CJ1M-CPU22 Manual.
A wide range of position control,
functions are available with,
this position control unit.