A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required.
No PC card is provided with the Unit.Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CJ1W-TC002 PROGRAMMING MANUAL.
Branching is easily made with CompoNet
CJ1W-TC002
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CJ1W-TC002 PROGRAMMING MANUAL. Product name: E@@S type CPU Units with 10 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 6; Outputs, 4;
Output type: Transistor (sourcing).
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.11A; 24 V,--.
Standards: UC1, N, L, CE CJ1W-TC002 PROGRAMMING MANUAL.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. I/O capacity: 1, 024 pts (4, 096 max. with remote I/O).
Execution time: Basic: 0.125 µs min.Special: 0.5 µs min.
Model: CPM2C-24EDT1. Units with 24 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ1W-TC002 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-TC002 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.