Specification: Thermocouple input (K, J, L, T, R, S, B),
ON/OFF or advanced PID control,
manual op-eration,
transistor (NPN) output, 4 loops.Model : C500-PS223.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.Name: Temperature Control Module.
Model: C200H-TC101 CP1E-N30SDT1-D OPERATION MANUAL.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Transistor output
CP1E-N30SDT1-DProduct name: E@@S type CPU Units with 10 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 6; Outputs, 4;
Output type: Relay.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.08A; 24 V,0.04A.
Standards: UC1, N, L, CE CP1E-N30SDT1-D OPERATION MANUAL.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508 CP1E-N30SDT1-D OPERATION MANUAL. 4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1E-N30SDT1-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N30SDT1-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.