100 to 120/200 to 240 VAC (Supports SYSMAC LINK and SYSMAC NET Link Systems.)Output method: Transistor sinking.
Inputs: ---.
Outputs: 8.Applicable CPU Units: CQM1H-CPU51/61.
Mounting locations/No. of Boards: One in Inner Board slot 2 (right slot).
Pulse inputs: 4 inputs.
Pulse outputs: 2 outputs.
Dimensions: 25 × 110 × 107 mm (W × H × D) CP1L-M40DT-D INSTRUCTIONS REFERENCE MANUAL.
Weight: 90 g max
CP1L-M40DT-D
Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System,
or Single CPU System;
Duplexing, Not supported;
Online Replacement, Not supported;
Mounting Backplane,CPU Backplane;
Connecting Cable,
Long-distance Connecting Cable.
Current consumption: 5V system, 0.92A;
26V system, -- CP1L-M40DT-D INSTRUCTIONS REFERENCE MANUAL.
Standards: U, C, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV001.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Transistor output.CV500-RT SYSMAC BUS Remote I/O Slave Unit (wired) CV500-RT221 CP1L-M40DT-D INSTRUCTIONS REFERENCE MANUAL.
Wire Type.Model : CVM1-PRS21-EV2.
For ladder.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CP1L-M40DT-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L-M40DT-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.