OMRON
Home >> Download >> OMRON >> Manual Download >> GX-ID1628 INSTRUCTION MANUAL ()

GX-ID1628 INSTRUCTION MANUAL ()

Brand: OMRON
Product model: GX-ID1628
Name: Digital Temperature Controllers
Sort: INSTRUCTION MANUAL
File language: English
File size: 1.67MB
Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available GX-ID1628 INSTRUCTION MANUAL.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires GX-ID1628
DIN track mounting. Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in GX-ID1628 INSTRUCTION MANUAL.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) GX-ID1628 INSTRUCTION MANUAL.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min.
(between each input terminal and the G terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the G terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion uniit per one I/O terminal unit GX-ID1628 Manual. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software GX-ID1628 Manual.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.
Related products
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-ID1618
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-ID1618
Input capacity: 16 points. Internal I/O comm
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-MD1628
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-MD1628
Internal I/O common: PNP. I/O indicators: LE
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-ID3218
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-ID3218
Input capacity: 32 points. Internal I/O comm
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-ID1622
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-ID1622
Input capacity: 16 points. Internal I/O comm