OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-PNB-L2AT11 Communications Manual ()

K3HB-PNB-L2AT11 Communications Manual ()

Brand: OMRON
Product model: K3HB-PNB-L2AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.85MB
A compact converter that allows,
communications between RS-232C/USB and,
RS-422/485 devices. Ideal for industrial,
applications.
Allows communications between RS-232C/USB (Universal,
Serial Bus) and RS-422/485 devices.
Applicable in FA environments: Has passed environment,
resistance tests equivalent to those for control devices K3HB-PNB-L2AT11 Communications Manual.
CE marking (except for USB) K3HB-PNB-L2AT11
UL/CSA certification (mark license recognition).
Compact 30-mm-wide body supports both screw-mounting and,
DIN track mounting.
Operation either with or without echoback available.
Functionality to convert between USB and RS-232C,
communications added.
USB driver providing virtual communications port for USB,
communications is available K3HB-PNB-L2AT11 Communications Manual. Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed K3HB-PNB-L2AT11 Communications Manual.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K3HB-PNB-L2AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PNB-L2AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Voltage and current panel meter
K3HB-XVD-L2AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-L2AT11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Time interval table
K3HB-PPB-L2AT11 AC100-240
OMRON Time interval table K3HB-PPB-L2AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Time interval table
K3HB-PNB-L2AT11 AC100-240
OMRON Time interval table K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PNB-L1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-L1AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E