OMRON
Home >> Download >> OMRON >> Manual Download >> K3HB-VLC-BBCD1 Communications Manual ()

K3HB-VLC-BBCD1 Communications Manual ()

Brand: OMRON
Product model: K3HB-VLC-BBCD1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Input type: DC voltage input type.
Output type: DeviceNet; -; DeviceNet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC-BBCD1 Communications Manual K3HB-VLC-BBCD1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Input type: DC voltage/current K3HB-VLC-BBCD1 Communications Manual.
Supply voltage: 24 VAC/VDC.
Comparative Output Model: None.
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaling, front-panel forced-zero, zero-limit functions.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate) K3HB-VLC-BBCD1 Communications Manual.
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking. Model: DGR-H (67G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal triibutaries K3HB-VLC-BBCD1 Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-VLC-BBCD1 Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-CPBC11 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC100-240
Category: external supply 100mA DC5V type. I