Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: DPDT ×1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON K3HB-VLC-CPEC11 Communications Manual.
Supports phase loss detection when the motor is operating K3HB-VLC-CPEC11
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three K3HB-VLC-CPEC11 Communications Manual.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-VLC-CPEC11 Communications Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K3HB-VLC-CPEC11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-CPEC11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-B1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-B1 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-EBCD1 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-EBCD1 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-B-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-B-DRT1 AC100-240
Category: external supply 100mA DC10V. Input